3.More attention:
1. During the installation, pay attention to the assembly dimensions of all parts of the fuselage and keep the straightness of the whole machine.
2. Tighten bolts when installing bolt fasteners.
3. The center line of the belt at both ends shall be aligned when making the belt joint to prevent the belt from running off.
4. When installing the protection part of the electric appliance, be careful to prevent damage.
| Model | TD75-5032 |
| HS | 8428330000 |
| Belt Width | 500mm |
| Conveyor Length | 10 meters |
| Belt Speed | 1.0m/s-2.0m/s |
| Lifting Height | 3 meters |
| Power | 4KW |
| Voltages | 220V/230V/380V/415V |
4.Maintenance and repair of fixed belt conveyor machine
4.1 under normal conditions, the conveyor is required to start without load and avoid short-time starting.
4.2 it is necessary to check whether there is oil leakage in the reducer regularly, and whether the regular oil filling volume is in conformity with the construction in time
Correct and supplement.
4.3 if there is squeal at the driving drum, it means that the belt is slipping. Check whether the belt is tensioned.
4.4 the belt joint shall be inspected frequently, and the damaged parts shall be cut and redone in time, and the damaged parts shall be protected during redoing
5.Tech data of fixed belt conveyor machine
| Main technical parameters |
| Bearing roller form | Bend speed | Bend width(mm) |
| (m/s) | 500 | 650 | 800 | 100 | 1200 | 1400 |
| | Conveying capacityQ(m3/h) |
| Through roller | 0.8 | 78 | 138 | - | - | - | - |
| 1.0~2.5 | 97~232 | 164~391 | 278~661 | 435~1033 | 655~1556 | 891~2118 |
| 3.15 | - | - | 821 | 123.3 | 1858 | 2528 |
| 4 | - | - | - | - | 2202 | 2996 |
| Flat roller | 0.8 | 41 | 67 | 118 | - | - | - |
| 1.0~2.5 | 52~125 | 88~211 | 147~350 | 230~546 | 345~821 | 467~1117 |
| Power (kw) | 1.5~40 | 1.5~50 | 2.2~75 | 4~100 | 7~185 | 4~185 |